About This Product
Specifications
FCT-01-10V Output:
±10VDC
FCT-01-420m Output:
4-20mA
bipolar:
-75mV in:4mA out, 0mV in:12mA out, 75mV in:20mA out
unipolar:
0mV in:4mA out, 75mV in:20mA out
Bandwidth:
-3dB @ 1500Hz
Gain:
Adjustable: typically set to 133.3 which yields 10VDC out for a 0.075V input from a standard 75mV shunt.
Gain Drift:
25 ppm/°C max
Isolation:
Uses a 3 port isolation amplifier (input, output and power supply) with ±3500 VDC isolation between any two ports.
CMRR:
Min. 80dB typical 85dB
Nonlinearity:
±0.012%
Cables:
Requires input (high voltage), output and power
Power Supply:
120VAC @ 60Hz. or 24 – 36 VDC supply
Operating temperature:
-40°C to +85°C
Dimensions:
8″L x 4.7″W x 4″D
Weight:
1.6Kg (3.2Kg with cables)
Options:
High voltage test leads with alligator clips
Model Numbers:
FCT-01-10V Field Current Transducer 0-10V out
FCT-01-420M Field Current Transducer 4-20mA out
Delivery:
Typically 4 – 6 weeks